
Maintenance Object Repair Procedures
555-233-123
10-1762
Issue 4 May 2002
Table 10-647.
TEST #6 NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one minute intervals a maximum of
5 times.
1000
ABORT
System resources required to run this test are not available.
The trunk may be busy with a valid call. Use display trunk xx
to determine the trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the
service state indicates that the port is in use, the port is
unavailable for certain tests. (Refer to “Status Commands”
section in
Chapter 8, ‘‘Maintenance Commands and
for a full description of all possible
states.) You must wait until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no
connected ports), check the Error Log for Error Type 1025
(see Error Log table for description of this error and
required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1001
ABORT
System resources required to run this test are not available.
This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS Maintenance to diagnose any active TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one minute
intervals a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...