Maintenance Object Repair Procedures
555-233-123
10-1500
Issue 4 May 2002
Table 10-572.
TEST #318 Shadow Link Test
Error
Code
Test
Result
Description/Recommendation
1029
2011
2012
2013
2014
2018
2020
2024
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1960
ABORT
The active SPE is currently locked on-line or one of the DUPINT
circuit packs is missing or broken.
1. If the active SPE is locked on-line, move the SPE select
switches back to the AUTO position and rerun the test.
2. If the active SPE is not locked on-line, check for DUPINT
errors and resolve those before rerunning the test.
1961
ABORT
The tested Common Shadow Circuit fiber cable is missing or
connected improperly or the Active/Standby DUPINT circuit pack
is defective.
1. Verify that the Common Shadow Circuit fiber cable on the
Standby/Active SPE DUPINT circuit pack is present and
connected properly.
2. Rerun the test. If the test still fails, replace the cable.
3. Rerun the test. If the test still fails, then one of the DUPINT
circuit packs may be defective.
a. Replace the standby DUPINT circuit pack first.
b. If the test still fails, then perform a lock switch
interchange.
NOTE:
This results in a COLD-1 SPE reset on the new active
SPE.
c. Then replace the DUPINT circuit pack in the new standby
SPE with the DUPINT circuit pack that was removed in
the previous step.
4. Rerun the test.
5. Test the Standby SPE with the test spe-standby short
command, and address all Duplication Interface circuit pack,
Common Shadow Circuit, and Maintenance/Tape Processor
tests that do not pass.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...