ANL-24-L (24-Port Analog Line)
Issue 4 May 2002
10-57
555-233-123
Station Present Test (also called Ringing
Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether terminal equipment is
connected to the port. This test may cause some terminal equipment to ring briefly
during daily maintenance. If this ringing disturbs the customer or the terminal
equipment, you can disable it via the Tests field on the change station form.
However, on some software releases, Tests #6, 7, 161, and 35 are disabled.
Table 10-22. TEST #48 Station Present Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call.
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted.
1. Use the display port PCSSpp command to determine
the station extension.
2. Use the status station command to determine the
service state of the port.
3. If the port is in use, wait until the port is idle and retry the
command at 1-minute intervals a maximum of 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test
may not be applicable or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or Music On Hold).
1008
ABORT
Could not allocate a ringing circuit. Either all the ringing
circuits are in use or the ringing generator is defective or it is
not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, look for RING-GEN errors in
the Error Log. If an ABORT 1008 occurs for this test on
other circuit packs as well, then the ringing generator may
be defective or is not wired correctly (see errors for
RING-GEN). If it does not occur on other ports, then all
four ring phases are in use.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...