Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-500
Issue 4 May 2002
Initcauses
Executing display initcauses shows the software upgrade and the system reset
level.
Multi-User Contention
When this command is executing, all other maintenance commands are blocked.
Exceptions to these are most of the status or display commands. All
administration commands are not blocked. It is the user’s responsibility to make
sure that no new translations are added between the last save translation
operation and the completion of the upgrade software command.
Recent Change History Log
The upgrade software command does not log for both simplex and duplex
systems. This is due to the clearing of memory during the level 4 reset.
Periodic and Scheduled Maintenance
Periodic and scheduled maintenance is suspended during the upgrade.
Error and Alarm Log
Error and alarm logs before the software upgrade are lost.
Demand Busyout Objects
Maintenance objects that have been demand busyout are released when the
processor reboots or interchanges during the software upgrade. If the command
is cancelled before the actual reboot or interchange starts, then all demand
busyout objects status are preserved.
Data Consistency between SPEs
Data consistency alarms are generated if the software in the active and standby
SPE are not consistent.
Disabled Objects
All disabled objects retain their “disabled” status after a software upgrade
according to the status recorded in the last save translation command.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...