CO-DS1 (DS1 CO Trunk)
Issue 4 May 2002
10-423
555-233-123
Table 10-159.
TEST #6 NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test were not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no
calls), check the error log for error type 1025 (see the error
log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
1001
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to the
TDM-BUS (TDM Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...