PR-MEM (TN2404/TN790 RISC Memory)
Issue 4 May 2002
10-1401
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. This error (3) indicates that a software patch has been applied and either
the software patch is bad or was installed incorrectly.
1.Back out the software patch and run the test memory UUCS long
command to verify that the problem has been cleared.
2.If the PBX system is equipped with High Reliability or Critical Reliability
option (i.e. with duplicated SPEs), and this error occurs, a SPE
interchange will occur if the health of the standby SPE permits the
interchange.
b. The following Aux Data indicate SIMM Failures
1.SIMM A
2.SIMM B
3.SIMM A & SIMM B
4.SIMM C
5.SIMM A & SIMM C
6.SIMM B & SIMM C
7.SIMM A, SIMM B, & SIMM C
Table 10-522.
Memory Error Log Entries
Error
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test memory a/b l r 1
1
Any
Flash Memory
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
3(a)
Any
Flash Memory
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
1025
Any
Memory Parity Error
Detection Test (#87)
MINOR
ON
test memory a/b r 3
1281
Any
Memory Burst Read
Test (#908)
MAJOR
ON
test memory a/b l r 2
1793
Any (b)(c)
Read All Memory (#85)
MAJOR
ON
test memory a/b l r 1
2049(d)
Any (b)(c)
Memory Functional
Test (#332)
MAJOR
ON
test memory a/b l r 1
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...