Maintenance Object Repair Procedures
555-233-123
10-1012
Issue 4 May 2002
License-
Error
Warning mode; call
processing supported,
6-day countdown
timer begins.
If you log in to the SAT and the message appears:
License-Error: xxxxx; Call Processing
Will Be Blocked in Approximately X
hours,
the ’xxxx’ tells you why you are in License-Error mode, and
call processing functions normally for ’X’ hours, at which
time the system goes into No-License mode.
One of the following conditions is present:
■
Active processor serial number does not match
the License File.
■
The License File has expired.
■
Feature usage does not match the License File.
■
A new license was not installed after an upgrade.
Clear the License-Error mode by
■
Correcting the error or mismatch that caused
going into this mode.
■
Installing a valid License File that is consistent
with the switch.
No-License
Outgoing and
incoming calls only to
administered
emergency numbers.
If you initially login to the SAT if you get a message that
says:
No-License: xxxxx; Call Processing
Blocked
, the ’xxxx’ tells you why you are in No-License
mode, and no call processing is allowed. Calls in progress
continue but all new originations are denied.
One of the following conditions is present:
■
No License File is installed in the system.
■
The License-Error timer expired.
■
A reset system 3 preserve-license command
has executed and the Offer Category in
translations does not match the License File.
Clear No-License mode by:
■
Correcting the error or mismatch that caused
going into this mode.
■
Installing a valid License File that is consistent
with the switch parameters.
Table 10-365.
Error messages and repair procedures — Continued
License
Mode
Description
Explanation and repair procedure
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...