Maintenance Object Repair Procedures
555-233-123
10-1216
Issue 4 May 2002
Table 10-453.
TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available. The
port may be in use on a valid call. Use the status pri-endpoint
<extension> command to determine when the port is available
for testing.
1004
ABORT
The port has been seized by a user for a valid call. Use the status
pri-endpoint <extension> command to determine when the port
is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1020
ABORT
The test did not run due either to an already existing error on the
specific port or to a more general circuit pack error.
1. Examine Error Log for existing errors against this port or
against the circuit pack, and attempt to diagnose the already
existing error.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly.
This causes noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not
use the conferencing feature on the NPE, this failure
indicates problems with the circuit pack hardware.
PASS
The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated by
using the other port tests and by examining the terminal adapter
or the external wiring.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...