Maintenance Object Repair Procedures
555-233-123
10-1386
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The MTP Reset Test (#101) has failed.
b. The MTP Sanity Handshake Test (#106) has failed.
c. The MTP Analog Loop Around Test (#103) has failed.
d. The MTP Dual Port Ram Test (#104) has failed. An error of 769 with an aux
data of 5 indicates a hardware problem and testing will not clear it. The
circuit pack should be replaced.
e. The MTP Outpulse Relay Test (#102) has failed.
f. The MTP Manager I Loop Around Test (#228) has failed.
g. The MTP Aux Loop Around Test (#229) has failed.
NOTE:
Refer to the FAIL section of each test that fails for further instructions.
Table 10-514.
Maintenance/Tape Processor Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1
1
You must manually repeat the command with the “long” option the designated number of times from
the administration terminal or from a remote administration terminal because the Sanity Timer Test
(#83) logs you off.
0
2
2
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test processor a/b sh r 1
1 (a)
Any
MTP Reset Test (#101)
MIN
ON
test processor a/b l r 3
257 (b)
Any
MTP Sanity Handshake Test
(#106)
test processor a/b r 2
513 (c)
Any
MTP Analog Loop Around
Test (#103)
MIN
ON
test processor a/b r 8
769 (d)
Any
MTP Dual Port Ram Test
(#104)
MIN
ON
test processor a/b l r 3
1025 (e)
Any
MTP Outpulse Relay Test
(#102)
MIN
OFF
test processor a/b r 5
1537 (f)
Any
MTP Manager I Loop Around
Test (#228)
MIN
ON
test processor a/b r 3
1793 (g)
Any
MTP Aux Loop Around Test
(#229)
MIN
ON
test processor a/b r 3
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...