ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 4 May 2002
10-91
555-233-123
1020
ABORT
The test did not run due to a previously existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or
the circuit pack and attempt to diagnose the previously
existing error.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
Either a system allocation to get information about the port or
to put the port into a service state failed or the attempt to put
the port in connection with a tone source failed (this could be a
tone-clock problem). The tone-clock and tone detectors could
be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-32. TEST #6 NPE Crosstalk Test — Continued