UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1835
555-233-123
Incoming Dial Type
tone
rotary
mf (to other DEFINITYs only)
Wink Timer for wink type
300
Wink Timer for delay type
4500
Trunk Group form, Page 3 (Administrable Timers)
Incoming Disconnect
100
Incoming Glare Guard
800ms or higher
Incoming Dial Guard
10
Incoming Incomplete Dial Alarm
25 or higher
Incoming Partial Dial
18
PPS
10 or 20
Make (for PPS 10)
35
Break (for PPS 10)
65
Make (for PPS 20)
15
Break (for PPS 20)
35
Outgoing Disconnect
100
Outgoing Glare Guard
800 or higher
Outgoing Rotary Dial Interdigit
800
Outgoing Seizure Response
5
Table 10-665.
TN2242 administration — Continued
Field
Value
Continued on next page