CO-TRK (CO Trunk)
Issue 4 May 2002
10-455
555-233-123
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop around and conference capabilities of a CO
port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones. Each tone is
transmitted separately through the loop and checked.
Table 10-168.
TEST #33 Loop Around and Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
7
ABORT
Conference Circuit Test aborted.
129
ABORT
The 404-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
131
The 1004-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
133
The 2804-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
1. Retry the command at 1 minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no
calls), check the error log for error type 769 (see the Error
Log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...