DAT-LINE (Data Line)
Issue 5 October 2002
983
555-233-119
Digital Loop Around Test (#171)
The Digital Loop Around Test checks the Data Line’s ability to transmit and
receive data on the TDM Bus. Data is sent through Data Channel 3 (data channel
port 3) over the TDM Bus, internally looped through the Data Line back onto the
TDM Bus, and received again by Data Channel 3.
If data channel 3 is in use or not administered, this test aborts. This test may fail if
Network Control Data Channel 3 is not functioning properly. If there are any
DATA-CHL errors in the Error Log, refer to the DATA-BD (Data Channel Processor
circuit pack) Maintenance documentation to clear them up first. This test passes
regardless of any customer equipment that may be connected to the port, as long
as the port is not in use by the equipment.
Table 183.
TEST #171 Digital Loop Around Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may
be in use on a valid call. Use status data-module to determine when the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005
1007
ABORT
Data Channel 3 is not administered. This port is required to run this test.
1. Verify that data channel 3 is not administered with the list data-module
command. Administer data channel 3 with the add data-module
command, and run this test again.
1016
ABORT
Data Channel 3 is busy. The port may be in use on a valid call. Use status
data-module to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020
ABORT
The test did not run due to an already existing error on this port (Error Type
769).
1. Reseat the circuit pack and look in the Error Log. If Error Type 769 still
occurs on this port, replace the circuit pack.
2000
ABORT
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2003
ABORT
Failed to receive an off-hook from the Data Line.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...