Install DS1 CPE Loopback Jack (T1 Only)
Issue 5 October 2002
101
555-233-119
11. Terminate the test by entering test ds1-loop <location> end
cpe-loopback-jack-test. Wait about 30 seconds for the DS1 to re-frame
on the incoming signal and clear DS1 facility alarms.
Loopback termination fails under the following conditions:
a. The span is still looped somewhere. This could be at the loopback
jack, at the ICSU, or somewhere in the network. This state is
indicated by a fail code of 1313. If the red LED on the loopback jack
is on, replace the ICSU. Re-run the test and verify that the loopback
test terminates properly. If not, replace the DS1 circuit pack and
repeat the test.
b. The DS1 cannot frame on the incoming span’s signal after the
loopback jack is powered down. This means that there is something
wrong with the receive signal into the loopback jack from the “dumb”
block or the Smart Jack. If the service provider successfully looped
and tested the span, up to the Smart Jack, this condition isolates the
problem to the wiring between the loopback jack and the Smart
Jack. See
‘‘Loopback Jack Fault Isolation Procedures’’ on page 101
for information on how to proceed in this case. The test cannot be
successfully terminated until a good signal is received. To properly
terminate the test before a good receive signal is available, enter
reset board <location>.
12. Restore the
TX LBO
field to the original value recorded in Step 2.
13. Release the DS1 circuit pack using the release board PCSSpp command.
14. Leave the loopback jack connected to the DS1 span.
Loopback Jack Fault Isolation Procedures
This section describes the possible DS1 configurations in which the loopback jack
may be used. These configurations are: when the DS1 provider includes a Smart
Jack, when no Smart Jack is provided at all, and when sites use fiber multiplexers.
Configurations Using a Smart Jack
The addition of the loopback jack and the presence of a Smart Jack divides the
DS1 span into 3 separate sections for fault isolation. These sections are shown in
Figure 9 on page 103
through
Figure 11 on page 105
for the different span
configurations. They are:
Section 1
Between the 120A2 (or later) ICSU and the loopback jack.
Section 2
Between the loopback jack and the Smart Jack (network
interface point).
Section 3
From the Smart Jack to the CO. It is necessary to contact the
DS1 provider to run this test.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...