SYNC (Synchronization)
Issue 5 October 2002
1599
555-233-119
Notes:
a. This error indicates a problem with the primary DS1 reference. It is cleared
when the primary reference is restored. The following steps should give an
indication of the source of the problem:
1. Check if the primary DS1 interface circuit pack is inserted in the
carrier via the list configuration board PCSS command.
2. Check the connection of the cable supplying the external timing
source to the primary DS1 interface circuit pack.
3. Test the primary DS1 interface circuit pack via the test board PCSS
long command. Check the Error Log for DS1-BD errors and refer to
the DS1-BD (DS1 Interface Circuit Pack) Maintenance
documentation to resolve any errors associated with the primary
DS1 interface circuit pack. If no errors are listed in the Error Log for
the primary DS1 interface circuit pack, continue with the following
steps.
4. Test the active Tone-Clock circuit pack in the master port network
via the test tone/clock PC long command. Check the Error Log for
TDM-CLK errors and verify that TDM Bus Clock Test #148 passes
successfully. If Test #148 fails with an Error Code 2 through 32, refer
to
‘‘TDM-CLK (TDM Bus Clock)’’
to resolve the problem. If not,
continue with the following steps.
1793
4
0-50
None
MAJOR/
WARNING
OFF
enable sync
2049 (f) (h)
4
0
None
WARNING
OFF
None
2305 (g) (h)
4
0
None
WARNING
OFF
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the value of set options, then, after a period of time, a Minor or
Major alarm is raised.
3.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
4.
It may take up to one hour for these SYNC alarms to clear due to "leaky bucket" strategy.
Table 460.
Synchronization Error Log Entries —
Continued
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...