Maintenance Commands
555-233-119
548
Issue 5 October 2002
test eda-external-device-alrm
Use test eda-external-device-alrm to run a hardware diagnostic test on all or
specific port’s administered external device alarms. The test PASSES if the
external device is not reporting an external device alarm and FAILS if the external
device is reporting an external device alarm. If you enter a specific port, it must be
administered as an external device alarm port on a maintenance or an analog line
port carrier board.
Action/Object
Qualifier
Qualifier Description
Logins
Default
Feature
Interactions
test
eda-external-
device-alrm
physical
location
all
repeat
clear
schedule
In addition to the word physical, you
must enter the physical location
(PCSSpp for an administered external
device alarm analog line port).
1
Tests all administered external device
alarm ports on analog line and
maintenance boards.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
sequence fails.
2
Use the screen to schedule execution of
the command. The command is placed in
the command queue and is executed at
the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
3
Examples:
test eda-external-device-alrm all
test eda-external-device-alrm all
schedule
test eda-external-device-alrm physical
1major r 10
test eda-external-device-alrm physical
2c1101 c
1
Since the “maintenance board” alarm connections connect to control carrier boards that are in unnumbered
slots, the standard port format cannot be used to designate these alarm connections. The special ports Pmajor
and Pminor are used designate the major or minor maintenance board alarm connection for cabinet P. The
major/minor designation specifies the pair of wires, not the alarm level associated with the connection (the
“major” port can be administered as a major, minor or warning alarm and the “minor” port can be administered
as a major, minor or warning alarm).
2
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
3
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Repeat
= 1
none
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...