HYB-LINE (Hybrid Line)
Issue 5 October 2002
1239
555-233-119
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors (if
any).
c. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure port is released from busyout via the
release port PCSSpp command.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. This indicates that the EPF has been turned off due to an overcurrent
condition at the voice terminal. Check for defective wiring or a damaged
jack, and make sure the voice terminal is a Hybrid set. Once the problem
has been resolved, the alarm is retired after a predetermined period of
time.
f. This indicates that the voice terminal has probably been disconnected or
that there is a problem in the wiring to the terminal. Make sure that the
voice terminal is connected or check for defective wiring to the voice
terminal.
g. Note that Error Types 769 and 1281 by themselves create Warning alarms
only, but if both are present, a Minor alarm is logged.
h. This indicates that there is something wrong with the data link to the voice
terminal. An in-line maintenance error has generated an off-board warning.
Ignore it if there are no complaints. Otherwise, make sure the voice
terminal is connected, check for defective wiring, check for a defective
voice terminal, and move voice terminal closer to the switch (in terms of
feet of wire from the jack to the switch). If the problem still exists, replace
the circuit pack.
i. This indicates that the station went off-hook while in the disconnect state.
Use the status station command to determine the state of the station. The
off-hook should have moved the station to in-service. No system technician
action is necessary.
j. This is the code that is generated when the link between the circuit pack
and the voice terminal is successfully reset. No system technician action is
necessary.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...