DS1-BD (DS1 Interface Circuit Pack)
Issue 5 October 2002
1089
555-233-119
FAIL
DS1 Interface circuit pack detects a Loss of Signal alarm. The physical link is
broken or the remote DS1 endpoint is down. All trunks or ports of this DS1
interface circuit pack are out-of-service. If the DS1 Interface circuit pack is
designated as the supplier of the system synchronization source, then the
system synchronization maintenance will adopt a source elsewhere. Refer to
"SYNC (Synchronization)" section for details.
1. If the DS1 Interface circuit pack connects to a T1 facility, call the vendor
of the T1 carrier to diagnose the remote DS1 endpoint. If the DS1
Interface circuit pack connects directly to a switch, call the system
technician of the remote switch to diagnose the DS1 endpoint.
2. Check the physical connection of the DS1 Interface circuit pack and the
cable. If a 120A1 CSU Module/T1 Sync Splitter is physically connected to
a TN767E board on the back of the port carrier, check the physical
connection of the CSU Module/T1 Sync Splitter and make sure the
Network Interface cable is plugged into the CSU Module’s/T1 Sync
Splitter’s NETWORK jack.
1300
FAIL
The CSU Module or the T1 Sync Splitter is missing. The Near-End CSU Type
field on the add ds1 form has been administered as integrated but the 120A1
CSU Module/T1 Sync Splitter is not physically connected to the TN767E
board on the back of the port carrier.
1. If using the 120A1 CSU Module/T1 Sync Splitter, plug the CSU
Module/T1 Sync Splitter into the TN767E circuit pack’s connector on the
I/O connector panel on back of the carrier. Otherwise, change the
Near-End CSU Type field using the change ds1 form to other.
2. Run the test again.
1301
FAIL
The 120A1 CSU Module or the T1 Sync Splitter is physically connected to the
TN767E board on the back of the port carrier but the Near-End CSU Type
field on the add ds1 form has not been administered as integrated.
1. If the 120A1 CSU Module/T1 Sync Splitter is to be used, use the change
ds1 command to change the Near-End CSU Type field to integrated.
Otherwise, physically remove the 120A1 CSU Module/T1 Sync Splitter
from the back of the port carrier.
2. Run the test again.
1302
FAIL
Attempting to use the 120A1 CSU Module with a TN767E circuit pack that is
configured for 32-channel (2.048 Mbps) operation. The CSU Module only
works with a DS1 board configured for 24-channel (1.544 Mbps) operation in
the United States of America.
1. If the 120A1 CSU Module is to be used, physically remove the TN767E
circuit pack and reconfigure for 24-channel (1.544 Mbps) operation.
2. Reinsert the circuit pack and run the test again.
Table 227.
TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...