Maintenance Objects
555-233-119
894
Issue 5 October 2002
1003
ABORT
The system could not allocate a Tone-Clock circuit pack for the test
connection. This situation could occur when the system is heavily loaded or
if a Tone-Clock circuit pack is not present in the port network when this test
is executed.
1. Verify the existence of a Tone-Clock circuit pack in the same port
network.
2. If a Tone-Clock circuit pack is missing, install one in the same port
network.
3. Allow approximately 1 minute for the Tone-Clock circuit pack
maintenance to run on the newly inserted Tone-Clock circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2006
ABORT
This abort code indicates that the active Tone-Clock circuit pack might not
be functioning properly. If there is more than one Tone Detector circuit pack
in the system, the problem can be either with the Tone-Clock circuit pack or
the Tone Detector circuit pack. This could also be caused by the
companding mode administered for the system not matching that of the
Tone Detector circuit pack.
1. Make sure that the companding mode of the system matches that of
the Tone Detector (TN748 for mu-law systems and TN420 for A-law
systems).
2. Test the active Tone-Clock circuit pack in the port network. This test is
being executed with test tone-clock qualifier system technician
command. (“qualifier” is the carrier of the active Tone-Clock circuit pack
to be tested. Valid qualifiers are: a, b, 1a, 1b, 2a, and 2b.) Refer to the
‘‘TONE-BD (Tone-Clock Circuit Pack)’’
Maintenance documentation for
details.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1-3
FAIL
DTMF digits were not detected correctly. This may or may not impact
reception of R2-MFC calls.
1. Run the short test sequence with test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore system performance to
normal, replace the Call Classifier circuit pack containing the defective
CLSFY-PT (Call Classifier Port).
Table 152.
TEST #42 Tone Detection Verification Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...