ATM-SGRP (ATM Signaling Group)
Issue 5 October 2002
751
555-233-119
Table 83. Descriptions and repair recommendations (Error Types 3840-3928)
Error
Code
Description
Recommendation
3842
A request has been made
to use a transit network or
common carrier that cannot
be accessed.
From the circuit pack and port number (in the Aux Data
field), determine the trunk group against which the error
was reported.
1. Check all routing patterns containing this trunk group
for validity of interexchange carriers requested (IXC
field).
3846
The far-end switch has
indicated that the B-channel
(trunk) is not acceptable for
use in the call for which it
was requested.
This could indicate
■
an administration problem (for example, the local
switch and the far-end switch have different
B-channels administered)
■
a normal race condition (for example, the local switch
has requested use of a B-channel which the far-end
switch had just reserved for use on another call).
1. From the circuit pack and port number (in the Aux
Data field), determine the trunk group against which
the error was reported.
2. Issue the status trunk command for the indicated
trunk.
3. Refer to
Table 68 on page 728
in
‘‘ATM-BCH (ATM
B-Channel Trunk)’’
for recovery suggestions.
3858
Similar to Error Type 1. The
switch sent an ISDN
message to the far-end
switch or terminal adapter
which did not respond in the
allotted time.
1. Check for alarms and errors against link components
2. Check out other errors against
‘‘ATM-SGRP (ATM
Signaling Group)’’
,
‘‘ATM-TRK (Circuit Emulation
Service Circuit Pack)’’
, and other hardware
components on the link.
3878
The far-end switch has
indicated that the network is
not functioning correctly
and that the condition may
last a relatively long period
of time (for example,
immediately re-attempting
the call may not be
successful).
1. From the circuit pack and port number (in the Aux
Data field, determine the trunk group against which
the error was reported.
2. Consult with the network provider to determine the
nature and expected duration of the out of service
condition.
3. Consider modifying all routing patterns containing this
trunk group, to route calls around the network which is
out of service.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...