DATA-CHL (Data Channel)
Issue 5 October 2002
959
555-233-119
If this test aborts or fails, it is impossible to determine from this test alone whether
the defective DATA-CHL is the target DATA-CHL or the arbitrarily chosen
DATA-CHL, or if the problem lies with the TDM Bus, or Tone-Clock circuit pack.
The results of running Tests #107, #108, #110, and #111 on the DATA-CHL can be
used to determine whether the target DATA-CHL is defective.
NOTE:
If an Error Code is encountered recommending that an CDR, System
Printer, Journal Printer, and/or PMS Link be busied out, restore each busied
out link to service according to PRI-CDR/SEC-CDR (PRI-CDR Link),
SYS-PRNT (System Printer Link), JNL-PRNT (Journal Printer Link), or
PMS-PRNT/JNL-PRNT (PMS Printer Link) Maintenance documentation,
respectively, before concluding work on the problem.
Table 175.
TEST #109 Data Channel Remote Maintenance Loop Around Test
Error
Code
Test
Result
Description/Recommendation
4
ABORT
For this test, an Error Code of 4 can have 2 different meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. Internal system error
Note the results of Tests #110 and #111 in the Short Test Sequence for the
target DATA-CHL. If the results of Tests #110 and #111 are both PASS, then
there is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
1. Determine if the target DATA-CHL is in use for some other function (that
is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the
‘‘Status of Data Channels’’
section. If so, check for errors on the
function that is using the DATA-CHL. If there are no errors, there is a high
probability that the DATA-CHL is not defective. Proceed with the
remaining steps only if it is necessary to completely test the target
DATA-CHL.
2. If the target DATA-CHL is in use for some other function, busyout the
function (CDR Link, System Printer Link, Journal Printer Link, PMS Link)
or the DATA-CHL (secondary administration terminal connection only).
3. Retry the command at 1-minute intervals a maximum of 5 times.Restore
any busied out CDR, System Printer, Journal Printer, or PMS Link to
service before moving on to another activity.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...