555-233-119
1176
Issue 5 October 2002
1
FAIL
System software indicates at least one Ethernet link session is down (SOME
UP).
1. Isolate downed sessions (status port UUCSSpp or status link n).
2. Follow actions based on session information.
2
FAIL
System software indicates all Ethernet sessions are down (ALL DOWN).
1. Test the port (test port UUCSSpp) to verify the Ethernet Local
Looparound Test (#1278) result.
2. If test passes, wait for system software to indicate ALL UP.
3. If the test fails, check the destination and other components in the path.
4. If the destination and other components in the path are in-service, take
action based on session information.
PASS
All sessions are up.
Table 260.
TEST #1286 Session Status Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...