555-233-119
1008
Issue 5 October 2002
3
FAIL
The nonreflective 1004 Hz tone test of the port failed. An echo was
detected from the port. Poor quality transmission was detected to or from
the port. The problem may be off-board.
7
The conference capabilities of the port failed. Poor quality transmission was
detected to or from the port. The problem may be off-board.
129
The reflective 404-Hz tone test failed. Poor quality transmission was
detected to or from the port. The problem may be off-board.
131
The reflective 1004-Hz tone test failed. Poor quality transmission was
detected to or from the port. The problem may be off-board.
133
The reflective 2804-Hz tone test failed. Poor quality transmission was
detected to or from the port. The problem may be off-board.
!
CAUTION:
The port may still be operational, or the fault may be off-board
(connections or CO). Off-board problems also include incoming
seizures or off-hook port seizures during the test and, perhaps
somewhat unlikely, noise induced by adjacent electric power lines.
Customers having this problem should resolve it with their local
power company to temporarily alleviate the alarm caused by the
failure of this test. The test may be disabled from trunk administration
’Test’ field. This turns off all testing for that trunk group except for
tests 6 and 36.
Proceed as follows unless power or tone problems are suspected (see note
below).
1. To make sure the problem is on-board, disconnect the port from the
far-end and retry the test. Coordinate this with the CO, or do it after
busy hours.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the test
in the trunk group administration. If the retry passes and troubles have
been reported, coordinate isolation with the CO.
If the loop around and conference circuit test fails for all ports on a circuit
pack, a -5 volt power problem is indicated.
PASS
DID Trunk Loop Around and Conference Test is successful. This port is
functioning properly.
1. If users are reporting troubles, examine loop connections to the port
and refer problem to the CO.
Table 190.
TEST #33 Looparound and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...