RANL-STA (Remote Analog Line (Station) Port)
Issue 5 October 2002
1547
555-233-119
b. Error Type: 15 - is a software audit error that does not indicate hardware
malfunction. Run the Short Test Sequence and investigate associated
errors.
c. Error Type: 257 - is an in-line error and can only be resolved over time.
This error indicates that ringing voltage is absent. If only one analog circuit
pack in the system has this problem, then replace the circuit pack. If only
analog circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, then it is probably a problem with the ringing
generator.
d. Error Type: 513 -Test #48 may cause some terminal equipment to ring
briefly during daily maintenance. If this disturbs the customer or the
terminal equipment, disable it by setting the
Tests
field on the change
station extension form to
n
. On some software releases, this will also
disable Tests #7 and 35.
e. Error Type 2817 - indicates that the end-point caused a large number of
control channel messages to be sent to the switch within a short period of
time (50 or more CCMS uplinks within 10 seconds). The station will be
taken out-of-service for 30 seconds due to the hyperactivity. This may be
completely normal during heavy traffic periods.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery Feed
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Battery Feed Test (#35)
X
X
ND
Station Present Test (#48)
X
X
ND
Station Status and Translation Audits and Updates
Test (#36)
X
X
ND
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...