DLY-MTCE (MO-DAILY)
Issue 5 October 2002
1067
555-233-119
Some other command actions can also interfere with daily maintenance when
certain qualifiers are used in the command, or under certain circumstances. For
example, certain “test” commands, when used with the modifier “continuously”,
could potentially interfere with daily maintenance. However, such command
actions are not used typically by customer administrators doing routine
administration, and are less likely to disrupt daily maintenance routines than are
the add, change, duplicate, remove, and set command actions.
Incomplete Command Time-out
A time-out feature has been added to the MAINTENANCE-RELATED SYSTEM
PARAMETERS form (accessed by the command change system parameters
maintenance). This feature improves the operation of daily maintenance by
allowing maintenance routines to run that might otherwise not run. It also helps to
prevent the loss of translations that were not saved by the save translation
command, and were also not saved because daily maintenance was prevented
from running prior to the system reset. Highlights of the feature include:
■
Options for blank, 1, 2, 3, 4, 5, or 6 hours (the default is 2 hours)
■
The blank option indicates that the feature is not active
■
Only commands that block the running of daily maintenance (add, change,
duplicate, remove, and set) are affected
■
All logins will time-out if any of these commands are active for the
prescribed time (except for the “blank” option)
■
The feature applies to all logins, regardless of type (init, dadmin, craft,
inads) or permissions granted to the specific login ID of an administration
or maintenance user
■
The corresponding “time-out” entry is appended to the list history log
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...