change system-parameters maintenance
Issue 5 October 2002
185
555-233-119
Field descriptions
change system-parameters
maintenance
Enter change system-parameters maintenance to specify scheduled
maintenance operations and maintenance support functions. This command
activates and deactivates INADS alarm origination during repairs.
To deactivate alarm origination:
1. Enter change system-parameters maintenance and press
Return
.
The Maintenance-Related System Parameters screen appears.
2. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them later.
3. Enter neither in the Alarm Origination to OSS Numbers field.
4. Enter none in the CPE Alarm Activation Level field.
5. If daily Scheduled Maintenance is running and needs to be deactivated, set
the
Stop Time
field to one minute after the current time.
6. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the
Start Time
field to a time after the session ends.
7. For earlier releases of system software, disable Cleared Alarm Notification
and Restart Notification.
Stratum
Enter the current synchronization stratum (3, 4)
Primary
Appears when 4 is entered in the Stratum field.
Indicates the primary system synchronization source.
Leave blank for no synchronization.
Secondary
Appears when 4 is entered in the Stratum field.
Indicates the secondary system synchronization source.
Leave blank for no synchronization.
Location
Circuit pack location of all administered DS1 circuit packs (port network,
carrier and board slot)
Name
User-defined name for the DS1 circuit pack.
Slip
Enter y if DS1 circuit pack has slip alarm.
Port
Network
Appears when 3 is entered in the Stratum field.
Display-only field specifying the port network that supplies
synchronization through the tone clock circuit pack.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...