555-233-119
1252
Issue 5 October 2002
1,2,3
FAIL
No response was received within the allowable time period on one of the
transmissions to the terminal. This indicates that something is wrong with
the data link to the voice terminal. This could be a sleeping set problem or it
may be due to wiring or an unplugged or defective set.
1. Check for errors in the error log, for example, error 1537.
2. Remotely issue the busyout and release busy commands, and run
the short test sequence on the port to check for other errors associated
with the port or terminal.
3. Check the wiring to the set if it appears that the terminal is not
responding to any tests; otherwise, replace the terminal and rerun the
test.
4. If the test still fails, replace the circuit pack and reconnect the original
terminal.
PASS
Hybrid Line Remote Digital Loop Around Test passed. The hybrid circuit
pack is sending and receiving proper messages to and from the voice
terminal.
1. If problems still exist, investigate using other circuit pack tests and by
examining the station, wiring, and connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 292.
TEST #59 Hybrid Line Remote Digital Loop Around Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...