MMI-BD
Issue 5 October 2002
1399
555-233-119
e. The circuit pack detected an Angel on-board hardware failure. The
reported aux data values correspond to the following detected errors:
4352 - External RAM error
4253 - Internal RAM error
4355 - ROM Checksum error
4357 - Instruction set error
Reset the circuit pack by using the busyout board PCSS, reset board
PCSS, and release board PCSS commands. When reset, the circuit pack
executes a set of tests to detect the presence of any of the above faults.
The detection of one these errors during initialization causes the circuit
pack to lock up and appear insane to the system. See the repair
procedures in note b) for Error Type 1.
f. This MMI circuit pack reported a loss of MMI synchronization. Refer to Test
(#1123) for repair procedures.
g. A failure of the time slot interchanger has been detected. Reset the circuit
pack using the busyout board PCSS, reset board PCSS, and release
board PCSS commands. If the reset passes, then the on-board circuitry is
healthy. Retire the alarm using the test board PCSS long clear command
followed by release board PCSS.
h. The circuit pack is hyperactive; that is, it is flooding the switch with
messages sent over the control channel. The circuit pack is taken out of
service when a threshold number of these errors is reported to the switch.
Clear the alarm using the following commands: busyout board PCSS,
reset board PCSS, test board PCSS long clear, release board PCSS. If
the error recurs within 10 minutes, replace the circuit pack.
i. The TSI Cross Talk Test (#6) failed. See the description of this test and
follow the repair procedures.
j. The TSI Looparound Test (#1108) failed. See the description of this test
and follow the repair procedures.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...