Maintenance Objects
1476
Issue 5 October 2002
1
FAIL
The Private Link Broadcast looparound test failed. The Packet Interface will
enter a fatal fault state when this occurs and the Packet Interface
Maintenance software should put the Packet Interface in a out-of-service
state. Therefore by the time further action is taken, it is expected that the test
will abort with ABORT code 1137 and a demand reset should be used to test
the Packet Interface.
1. Reset the Packet Interface using the reset packet-interface AS
command. Refer to the repair procedures for the Packet Interface Reset
Test (#889) for further action.
2. If the test continues to fail, replace the TN2402/TN798 Processor circuit
pack.
2
FAIL
The Private Level 2 looparound test failed. The Packet Interface will enter a
fatal fault state when this occurs and the Packet Interface Maintenance
software should put the Packet Interface in a out-of-service state. Therefore
by the time further action is taken, it is expected that the test will abort with
ABORT code 1137 and a demand reset should be used to test the circuit
pack.
1. Reset the Packet Interface using the reset packet-interface AS
command. Refer to the repair procedures for the Packet Interface Reset
Test (#889) for further action.
2. If the test continues to fail, replace the TN2402/TN798 Processor circuit
pack.
PASS
All the private looparound tests passed. The Packet Interface is functioning
properly. If the system is still unable to place calls, then:
1. Display the error log (display errors) and check for errors on the Packet
Bus and Maintenance/Test circuit pack. Clear those errors first.
2. Check all other circuit packs connected to the Packet Bus. Packet Bus
failures are likely to be caused by a faulty circuit pack connected to the
backplane or bent pins on the back plane. Refer to the PKT-BUS
maintenance documentation for repair procedures.
Table 392.
TEST #885 Private Looparound Tests —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...