CUST-ALM (Customer-Provided Alarming Device)
Issue 5 October 2002
941
555-233-119
CUST-ALM (Customer-Provided
Alarming Device)
The system provides customers a way to connect their own alarm indication
device to a switch. The CUST-ALM maintenance object represents this
Customer-Provided Alarming Device (CPAD). When an alarm occurs at least to
the level to which the CPAD is administered, the CPAD in the Processor Port
Network (PPN) is activated. The CPAD is administered by the
Maintenance-Related System-Parameters Form (CPE Alarm Activation Level
field). The CPAD is connected to the Processor circuit pack. The valid levels to
which to set the CPE Alarm Activation Level are: none, warning, minor, or major.
The CPAD is also activated within a cabinet whenever Emergency Transfer is
invoked within that cabinet. The CUST-ALM MO is not maintained by the system
and does not generate any alarms. If a problem is suspected with the CPAD, it
may be tested using the test customer-alarm command, which activates the
device by closing the relay on the Processor circuit pack for 1 minute. The repeat
parameter may be used to close the relay for a longer length of time (5 minutes is
the suggested repeat value).
The CPAD is also activated within a cabinet whenever Emergency Transfer is
invoked within that cabinet. The CUST-ALM MO is not maintained by the system,
and does not generate any alarms. If a problem is suspected with the CPAD, it
may be tested using the test customer-alarm command, which activates the
device by closing the relay on either the Processor circuit pack for 1 minute. The
repeat parameter may be used to close the relay for a longer length of time (5
minutes is the suggested repeat value).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
Where PC is an appropriate port network number and carrier.
Full Name of MO
CUST-ALM
none
test customer-alarm PC
Customer-Provided Alarming Device
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...