TDM-CLK (TDM Bus Clock)
Issue 5 October 2002
1671
555-233-119
2. Otherwise, enter the display errors command, and follow corrective
procedures for any other TDM-CLK, TONE-BD, SYNC, DS1C-BD,
EXP-INTF, SNC-BD, and SNI-BD errors logged, except for those in
the following table.
3. If 1025 errors persist, refer to SYNC Maintenance.
h. Error Type 1281
This error is an indication that the Tone-Clock circuit
pack has detected a loss of timing signal from the system synchronization
reference. The Tone-Clock circuit pack has switched synchronization
references.
1. Resolve any errors logged against the SYNC or STRAT-13
maintenance objects.
2. Refer to SYNC maintenance if the error is not resolved by step 1
Error Type 1282
Indicates that the TN2182 tone-clock was synchronized
to a DS1 facility and that the reference frequency provided by the DS1
drifted beyond a range that could be tracked by the TN2182. Therefore the
TN2182 is no longer synchronized to that DS1 reference. If a second DS1
is available, the tone-clock may be synchronized to that reference. If no
secondary DS1 reference is available, the tone-clock will run off of its
internal clock. This may result in slips being reported by the tone-clock and
all DS1 facilities.
i. The tone-clock circuit pack in the master port network was unable to detect
the incoming synchronization signal, but the other tone-clock was able to
detect the references. If the aux data is 0, the problem is with the signal on
the primary. If the aux data is 1, the problem is with the signal on the
secondary. The system should switch clocks in this situation.
1. Replace the Tone-Clock circuit pack.
j. The indicated Tone-Clock circuit pack has detected a loss of timing signal.
1. Enter display errors and display alarms, and follow the associated
repair procedures for TDM-CLK error log entries that have on-board
alarms.
Error Log Entries for Slip Errors
Circuit Pack Name
Error Log
Name
Error Log Entry
for Slips
DS1 Interface
DS1-BD
3073 to 3160
Tone-Clock
TDM-CLK
1025
UDS1 Interface
UDS1-BD
3073 to 3160
DS1C Circuit Pack
DS1C-BD
3329
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...