ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
667
555-233-119
Loop Around and Conference Test (#47)
Each Analog Port consists of:
■
an NPE for port connectivity and gain, and conferencing functionality
■
a code that converts the digital signals of the TDM Bus to analog signals
■
a battery feed chip that provides power to the telephone set for signaling,
dial pulsing, transmission, and balance
This test is designed to check the on-board transmission capabilities of the NPE,
the code, and the battery feed chip of the Analog Port. A Tone Detector and a
Tone Generator talk and listen on the same pair of time slots as the Analog Port.
The Analog Port is instructed to go into loop around mode (see
Figure 19
). The
test passes if the signal measured by the Tone Detector is within acceptable
limits.
8
FAIL
This does not indicate a hardware problem but may be an internal software
error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, by examining the station, and by ensuring that the
terminal is correctly translated as off-premises or on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, Use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between
the internal ID and the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 47. TEST #36 Station Status and Translation Audits and Updates Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...