Maintenance Commands
555-233-119
488
Issue 5 October 2002
Field descriptions
Port
(cabinet/carrier/slot/circuit) of the ISDN-PRI B-channel.
Bit Error Rate
The measured bit error count based on the comparison between sent
and received bit patterns. (Number displays in scientific notation)
Number of Bits
Number of bits generated. (Number displays in scientific notation)
Block error Rate
The measured block error count based on the comparison between
sent and received bit patterns. (Number displays in scientific notation).
Number of Blocks
Number of blocks generated. (Number displays in scientific notation)
Start Time
Test call start time. (dd/hh:mm).
Duration
Specified
Specified run time for the test call. (1-120 minutes, or blank = default
of 10 seconds).
Duration of Test
Run time for the test call, listed in minutes. “blank” = a default time.
Reason of
Termination
Reason that the test call terminates: “finished,” “canceled,” “overflow,”
“no bits,” “transmission,” “internal fail,” “data corrupt,” “call dropped,”
“call rejected,” and “in progress.” “finished” = the test finishes in the
specified time. “canceled” = the test call cancels with the clear
isdn-testcall command. “overflow” = the transmitted bits overflow
buffer allocation. “no bits” = no bits are received because the
ISDN-PRI test call circuit connection is bad. “transmission” = a data
transmission interrupts, probably from a power hit. “call dropped” = the
call drops due to an abnormal termination, or inability to cut-through to
the other side. “call rejected” = the originating call is not set up
properly. “internal fail” = an internal error on the Maintenance/Test
circuit pack. “in progress” = the test is still running; “data corrupt” = any
other error condition.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...