555-233-119
1294
Issue 5 October 2002
3858
The switch sent an ISDN
message to the far-end
switch or terminal adapter
which did not respond in the
allotted time.
Possible causes include link failure and congestion or
outage at the far-end.
3878
The far-end switch has
indicated that the network is
not functioning correctly
and that the condition may
last a relatively long period
of time (for example,
immediately re-attempting
the call may not be
successful).
1. From the circuit pack and port number (in the Aux
Data field, determine the trunk group against which
the error was reported.
2. Consult with the network provider to determine the
nature and expected duration of the out of service
condition.
3. Consider modifying all routing patterns containing this
trunk group, to route calls around the network which
is out of service.
3890
A request to use a network
service (e.g., SDN) has
been denied. Administration
somewhere on the network
has indicated that the
requested service has not
been subscribed to or
purchased for this trunk.
This could be a local administration problem only, or a
mismatch between the local administration and that of the
network provider.
1. From the circuit pack and port number (in the Aux
Data field), determine the trunk group against which
the error was reported.
2. Display the trunk group form: If the trunk group is
Call-by-Call (Service Type is “cbc”), check all routing
pattern forms containing this trunk group to see if the
Service/Feature fields contain the correct network
services purchased for this trunk. If the trunk group is
not Call-by-Call, check that the Service Type field
contains the single network service purchased for this
trunk.
3. If local administration appears correct, consult with
the customer and/or the network provider to
determine the services that the customer has
subscribed to for this trunk group.
3892
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
If customer is complaining of unexpected intercept tones
when accessing ISDN trunks or PRI endpoints and no
other cause can be found, provide the next tier with this
Error Log information.
Table 309.
Descriptions of Error Codes 3842-3942 — Continued
Error
Code
Description
Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...