DATA-CHL (Data Channel)
Issue 5 October 2002
961
555-233-119
1000
ABORT
(cont’d.)
3. Issue the list data-module command to determine if other DATA-CHLs
are administered. If no other DATA-CHLs are administered, administer at
least one at this time.
4. Determine if the DATA-CHLs OTHER THAN the target DATA-CHL are all
in use for some other function (that is, CDR Link, System Printer Link,
Journal Printer Link, PMS Link, or secondary administration terminal
connection) as described previously in the “Status of Data Channels”
section. If so, and if it is necessary to completely test the target
DATA-CHL, use the following preference guidelines to free one of the
DATA-CHLs for testing.
a. If a DATA-CHL is being used for a secondary administration terminal
connection, busyout that DATA-CHL.
b. Otherwise, if a DATA-CHL is being used for a PMS Link, busyout the
PMS Link.
c. Otherwise, if a DATA-CHL is being used for a Journal Printer Link,
busyout the Journal Printer Link.
d. Otherwise, if a DATA-CHL is being used for an CDR Link, busyout the
CDR Link.
e. Otherwise, if a DATA-CHL is being used for a System Printer Link,
busyout the System Printer Link.
5. Retry the command at 1-minute intervals a maximum of 5 times.
6. Restore any busied out CDR, System Printer, Journal Printer, or PMS
Link to service before moving on to another activity.
1006
ABORT
For this test, an Error Code of 1006 can have one of several different
meanings:
a. No other DATA-CHLs are administered and, therefore, not available to
place the call to the target DATA-CHL.
b. All other DATA-CHLs are busy and, therefore, not available to place
the call to the target DATA-CHL.
c. System resources required to run this test are not available.
d. Internal system error
Note the results of Tests #110 and #111 in the Short Test Sequence for the
target DATA-CHL. If the results of Tests #110 and #111 are both PASS, then
there is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
Table 175.
TEST #109 Data Channel Remote Maintenance Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...