SYS-PRNT (System Printer)
Issue 5 October 2002
1609
555-233-119
Procedures for Restoring the System Printer Link
The following procedures should be followed to restore the System Printer Link:
1. Determine the status of the System Printer Link via the status sp-link
command. Verify that the System Printer Link is not busied out for
maintenance. On the System Printer Link Status Form, this is indicated by
a “no” in the “Maintenance Busy?” field. If the System Printer Link has been
busied out, issue the release sp-link command. If the link is “down,”
proceed to Step 2.
2. Issue the display system feature command to determine the destination
of the System Printer Link.
If the destination is an extension number, enter the status data-module
<extension> command and verify that the data extension is in-service/idle.
If the data extension is NOT available, refer to the "Port/Channel Number"
field on the "Data-Module Status" Form. Look for errors and/or alarms on
the circuit pack with which this extension is associated. Refer to the
appropriate MO documentation for recommended repair strategy. Continue
with Step 3.
If the destination is eia, look for PR-MAINT errors in the Hardware Error
Log. If errors are present, refer to Maintenance/Tape Processor
Maintenance documentation, and continue with Step 5.
3. Determine if a data channel on the Network Control circuit pack is
in-service/idle as follows:
a. Use the list data-module command to find out the extension
numbers of the data channels on the Network Control circuit pack.
(There is a maximum of 4. They are listed as “newton” on the Active
SPE. Ignore the Standby data channels.)
b. Enter the status data-module <extension> command to verify that
at least one Active data channel is in-service/idle.
4. If four data channels are administered and none are available, then look for
DATA-CHL/DATA-CON/DATA-BD errors in the Hardware Error Log. If
errors are present, refer to these MO sections for recommended
maintenance strategy. When problems (if any) with
DATA-CHL/DATA-CON/DATA-BD have been resolved, continue with Step
5.
If fewer than four data channels are administered, then use the add
data-module command to add a network control data module to the
system.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...