LIC-ERR (License-Error Mode)
Issue 5 October 2002
1331
555-233-119
3
LIC-ERR (License-Error Mode)
NOTE:
The License-Error Mode maintenance object (LIC-ERR) is a non-traditional
MO. As a result, there are no associated tests or commands that are
executed in the traditional manner.
Maintenance object LIC-ERR works in concert with maintenance object NO-LIC to
look for any errors/violations associated with the License File. Once a License File
error occurs, maintenance object LIC-ERR logs the error, raises an alarm, and
starts a timer that is associated with the error. When the timers threshold has
been exceeded, MO NO-LIC will cause call processing to be restricted. All call
origination will be restricted to outgoing emergency numbers, incoming calls will
be restricted to an Administration (Attendant Console) number.
The license file is loaded onto a switch during initialization of the switch software,
restore of translations, and periodically. After initialization, a query is made to a
software module called the License Server. This module reads the license file,
compares a serial number in the license file to a serial number in hardware,
compares the software version in the license with the running software version,
and if a match occurs, delivers permission to run to the Avaya MultiVantage
Software along with a new feature mask. The feature mask controls
revenue-associated options.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
LIC-ERR
MAJOR
NONE
License-Error Mode
Table 325.
LIC-ERR Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
1(a)
MAJOR
OFF
See footnote
1
1.
These Error Types can be cleared by providing the correct License File per local instructions.
513(b)
None
MAJOR
OFF
See footnote
1
769(c)
None
MAJOR
OFF
See footnote
1
1281(d)
None
MAJOR
OFF
See footnote
1
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...