XXX-BD (Common Port Circuit Pack)
Issue 5 October 2002
1911
555-233-119
XXX-BD (Common Port Circuit Pack)
The Common Port Circuit Pack Maintenance is a set of common tests used by all
the circuit packs with the generic hardware that interfaces with the TDM bus.
Circuit packs included in this category are listed on the following pages.
Notes:
a. All circuit pack suffixes (B,C, D, etc.) are also supported by the XXX-BD
(Common Port Circuit Pack) Maintenance documentation.
b. The XXX-BD designation is also used in the SAT display in the case where
a reset board command is issued to a circuit pack type which is in conflict
to the actual circuit pack type administered for that slot or when a reset
board command is issued to an empty circuit pack slot.
When any of the Common Port Circuit Packs (except the TN754 Digital Line and
TN758 Pooled Modem circuit packs) are physically removed from the backplane,
no alarm is logged for approximately 11 minutes. In the case of the Digital Line
and Pooled Modem circuit packs, approximately 21 minutes elapse before an
alarm is logged. When a circuit pack that has been removed is alarmed, the alarm
type is minor and is classified as an on-board alarm. The time delay permits
maintenance activity to be performed without triggering an additional alarm. An
alarm is logged only against a Common Port Circuit Pack on which ports
have been administered. See the next Note.
NOTE:
In a heavily loaded system, the interval between the removal of a Common
Port Circuit Pack and the logging of the alarm may be several minutes
longer.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
Where P is the port network number (1); C is the carrier designation (for example, A, B, or C); and
SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02, etc.)
Full Name of MO
XXX-BD
2
2.
Refer to the appropriate circuit pack documentation to get the correct MO name displayed in this
field. It usually ends with BD.
MAJOR
test board PCSS
Common Port Circuit Pack
Maintenance
XXX-BD
2
MINOR
test board PCSS
Common Port Circuit Pack
Maintenance
XXX-BD
2
WARNING
test board PCSS
Common Port Circuit Pack
Maintenance
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...