CO-TRK (CO Trunk)
Issue 5 October 2002
933
555-233-119
7,
FAIL
The conference capabilities of the port failed (Error Code 7).
129,
The reflective 404-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 129).
131, or
The reflective 1004-Hz Tone Test failed. No transmission was detected to
or from the port (Error Code 131).
133
The reflective 2804-Hz Tone Test failed. No transmission was detected to
or from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems
are suspected (see note below).
1. To make sure the problem is on-board, disconnect the port from the
CO and retry the test. Coordinate this with the CO, or do it after busy
hours; otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the
test. If the retry passes and troubles have been reported, refer the
problem to the CO.
NOTE:
If the looparound and conference circuit test fails for all ports on a
circuit pack, a -5 volt power problem is indicated. When the tone
errors are cleared, rerun the test. If the test fails again, see FAULT
ISOLATION above.
PASS
CO Trunk Loop Around and Conference Test is successful. User-reported
troubles on this port should be investigated by using other port tests and by
examining trunk or external wiring.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue busyout board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board. This should re-establish the linkage between the
internal ID and the port.
Table 164.
TEST #33 Loop Around and Conference Circuit Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...