Maintenance Objects
1522
Issue 5 October 2002
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP
into a loop around mode, and it verifies the data integrity of the channel. The
Auxiliary channel is used as the CDR output port.
Table 416.
TEST #229 MTP Auxiliary Loop Around Test
Error
Code
Test
Result
Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1000
ABORT
The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
The test has been disabled via administration. The change
system-parameters cdr command needs to administer CDR.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2033
2034
ABORT
Internal system error
Port busy
Retry the command at 1-minute intervals a maximum of 5 times.
22902
22903
ABORT
The system software resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The Auxiliary channel failed the Loop Back Test. The AUX port is probably not
sending any auxiliary data to the auxiliary collection device.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
PASS
The Auxiliary channel passed the Loop Back Test. The auxiliary port is
functioning correctly.
1. If no auxiliary data is being recorded, check the auxiliary collection
device, and verify that it has been set up and connected correctly.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...