DIG-LINE (Digital Line)
Issue 5 October 2002
1031
555-233-119
h. An in-line maintenance error has generated an off-board warning due to
some problem with the link to the voice terminal. This can be ignored if no
user complaints are received. Otherwise, make sure the voice terminal is
connected, check for defective wiring, check for a defective voice terminal,
and move voice terminal to a jack that is closer to the switch (in terms of
feet of wiring between the jack and the switch). If the problem still exists,
replace the circuit pack. Once the problem has been resolved, the alarm
will be retired after a predetermined amount of time.
i. This indicates that the station went off-hook while it was in the
ready-for-service state. Use the status station command to determine the
state of the station. The off-hook should have moved the station to
ready-for-service. No craft action is necessary.
j. Port Level Hyperactivity—Fifty or more CCMS uplilnk messages were
received from the port within ten seconds. The user is taken out of service
for a short interval of time (default 30 seconds).
k. No terminal is connected to the Digital Line board. No maintenance action
is required.
l. An uplink message has been logged indicating that the Electric Power
Feed (EPF) is on with no load on it. No action is necessary.
m. The circuit pack’s message buffer is full. This may be caused by having
many display phones with heavy traffic connected to the circuit pack. No
action is necessary.
n. Internal system error. No action is necessary.
o. There is a problem with the voice terminal EEPROM. When the voice
terminal is repaired the alarm will be resolved with the passing of time.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Voice and
Control Channel Local Loop Around Test, for example, you may also clear errors
generated from other tests in the testing sequence.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...