Maintenance Objects
555-233-119
920
Issue 5 October 2002
2561
57345
Single polarity ringing current. This error results
from abnormal ringing current, but does not
prevent the incoming call from being accepted.
One cause could be that the reverse current
detector associated with the port is failing. (Will
not be detected by any tests.) Another cause
could be that normal current is not detected. In
this case, neither incoming nor outgoing calls
can be completed, and the dial tone test also
fails. The last cause could be that certain types
of noise are present on the CO line during the
silent period of ringing.
Check for other errors and
see Note
4
at end of table.
2817
57360
Ground but no ringing. This error occurs on an
incoming call on a ground-start trunk. If ringing
is not detected within 5 seconds of the Tip being
grounded, the call is still accepted. If the CO is
of the No. 5ESS. switch type, ringing delays of
more than 5 seconds during heavy traffic are
fairly common.
Check for other errors.
2817
57393
On the TN465, the loop is opening too slowly
after a disconnect. This error indicates an
on-board problem, although the trunk may be
functional. On the TN2138, CO released the
trunk at least 4 minutes after the PBX dropped
the call. This error code is log-only and causes
no other testing to occur. No alarm is
generated.
Check for other errors.
3073
57376
No loop current on incoming call. The incoming
destination has already answered and no loop
current has been detected. If this is a hard fault,
the dial tone test and all outgoing calls should
also fail.
Check for other errors.
3329
57408
Trunk error. No Tip ground detected on
outgoing call. This error occurs when an
attempt is made to seize a ground-start CO
trunk for an outgoing call and Tip ground is not
detected or the caller hangs up before Tip
ground is detected.
See Notes
1
and
2
at end of
table.
3585
57424
No loop current on outgoing call. This error
occurs on attempt to seize a loop or
ground-start trunk for an outgoing call. An error
occurs if loop current is not detected or the
caller hangs up before it is detected.
See Note
3
at end of table.
Table 160.
CO Trunk Errors with NO Tests —
Continued
Error
Type
Aux
Data
Description and System Action
System Technician Action
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...