TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 5 October 2002
1647
555-233-119
Signaling Link State (#1251)
This test is nondestructive. This test checks the current state of the signaling link.
The test looks at the board-level translations, checks that the board is physically
inserted, gets the state of the D-Channel and service state of the port.
The test passes if the signaling link (D-Channel) is connected and operating
normally. The test fails if the board is not installed, the signaling link is
disconnected, or if the port is out of service. The test aborts otherwise.
Service State Audit (#256)
This test is nondestructive. This test performs a service state audit on an ISDN
B-Channel. The test passes if Call Processing informs Maintenance that the
Restart message was transmitted successfully, or if the B-Channel was busy and
could not send the message.
The test fails if the board is not inserted or translated properly, or if a reply is not
received within a certain amount of time.
The test aborts if the signaling link is disconnected, if a message is already
outstanding, or if the necessary resources could not be allocated. Maintenance
will take no action if the test aborts.
To investigate the service state of the TN2185 ISDN Trunk-Side BRI Channel,
issue the status trunk trunk-group/trunk-member command.
Table 482.
TEST #1251 Signaling Link State Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error
1018
ABORT
The test is disabled.
1. Enable the test by entering enable test #1251.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
8
FAIL
The signaling link is down.
1. Consult the procedures for the TBRI-PT maintenance object.
9
FAIL
The port is out of service.
1. Return the port too an in service state.
PASS
The signaling link is connected and operating normally.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...