DID-TRK (DID Trunk)
Issue 5 October 2002
1011
555-233-119
61446
FAIL
Battery feed test failed. A loop current fault was detected. This is most
probably an incoming CO-line problem. This failure code is only reported by
the TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is detected refer
the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the DID port.
Replace the circuit pack.
61456
FAIL
Battery feed test failed. An on-board problem was detected. This port is
out-of-service.
1. Replace circuit pack.
61472
FAIL
Battery feed test failed. A problem with the incoming CO-line was detected.
1. Check the incoming CO-line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the DID port.
Replace the circuit pack.
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be investigated using other
port tests and by examining connections.
2. Refer problem to the CO.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 191.
TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...