Maintenance for CSI systems
555-233-119
100
Issue 5 October 2002
9. Repeat Steps 5 through 8 as desired to observe bit error rate
characteristics. Also, wait 1 to 10 minutes between Steps 5 through 7. One
minute without errors translates to better than a 1 in 10 to the eighth error
rate. Ten minutes without errors translates to better than a 1 in 10 to the
ninth error rate.
10. If the test runs for 1 minute with an error count of 0, confirm that the 3-in-24
pattern error detector is operating properly by entering test ds1-loop
<location> inject-single-bit-error. This causes the 3-in-24 pattern
generator on the DS1 circuit pack to inject a single-bit error into the
transmit pattern. Type list meas ds1 summary <location> to display the
bit error count. If a count greater than 1 is displayed, replace the ICSU and
retest. If the problem continues, replace the DS1 circuit pack.
Bit Error Count
Cumulative
count of
detected
errors
If there are no wiring problems, the counter
remains at 0.
A count that pegs at 65535 or continues to
increment by several hundred to several thousand
on each list meas
command execution indicates
intermittent or corroded connections, severe
crosstalk, or impedance imbalances between the
two conductors of the receive pair or the transmit
pair. Wiring may need replacement.
Note that “ESF error events” counter and the ESF
performance counter summaries (“errored
seconds”, “bursty errored seconds”, and so forth)
will also increment. These counters are not used
with the loopback jack tests. However, they will
increment if errors are occurring. Counters should
be cleared following the test.
Table 8.
DS1 Span Troubleshooting —
Continued
Field
Function
Indication
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...