Maintenance Objects
555-233-119
650
Issue 5 October 2002
Station Present Test (also called Ringing
Application Test) (#48)
Test #48 applies momentary ringing voltage to phone equipment and monitors
resulting current flow to determine whether the equipment is connected to the
port. Test #48 may cause some phone equipment to ring briefly during daily
maintenance. If this disturbs the user or the phone equipment, to disable Test #48
use change station
extension
and set the
Tests
field to n. On some software
releases, this also disables Tests #6, 7, 161, 35, and 47.
5
FAIL
This may be an internal software error. The message waiting lamp update
failed. The translation and ringer updates were not performed because of
this failure.
7
FAIL
The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8
FAIL
This does not indicate a hardware problem. There may be an internal
software error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, or by examining the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure the board translations are correct. Use list config and
resolve problems.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between the
internal ID and the port. If this is not the case, check to ensure that there
is a valid board inserted.
Table 41. Test #36 Station Status and Translation Audits and Updates —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...