RDIG-STA (Remote Digital Station)
Issue 5 October 2002
1563
555-233-119
Table 440.
TEST #11 Digital Line Electronic Power Feed Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port
may be busy with a valid call. Enter display port UUCSSpp to
determine the station extension or attendant number of the port. Use
status station or status attendant to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
Attendants are always in use (off-hook) if the handset is plugged in
and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Electronic Power Feed Test passed. The message to turn on the
power to the station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except
for the Internal system error described above, it will log an error
indicating the real results of the test. Check the Error Log for any
entries with Error Types 767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, the test sensed no
problems with the power to the station. To verify that the station is
powered up correctly, run a self-test on the station and check that
all the feature buttons are operating.
3. If Error Type 769 appears in the Error Log, this indicates some
problem with the power to the station. Check for a short in the
wiring, a damaged jack, a defective voice terminal, or an incorrect
type of terminal.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...