UDS1-BD (UDS1 Interface Circuit Pack)
Issue 5 October 2002
1771
555-233-119
If this error remains after plugging the CSU Module/T1 Sync Splitter into
the board’s connector, there could be a problem with the I/O connector
panel.
E1 Synchronization Splitter missing: The
E1 Sync-Splitter?
field
on the add ds1 form has been administered as
y,
but the 402A or 403A
E1 Synchronization Splitter is not physically connected (or is improperly
connected) to the UDS1 board on the back of the port carrier.
If using the 402A or 403A E1 Synchronization Splitter, plug (or replug) the
E1SS into the UDS1 circuit pack’s connector on the I/O connector panel on
back of the carrier. Otherwise, change the
E1 Sync-Splitter?
field
using the change ds1 form to
n
.
If this error remains after plugging the E1SS into the board’s connector,
there could be a problem with the I/O connector panel.
k. Error Type 1301 — CSU Module/T1 Sync Splitter not expected or E1
Synchronization Splitter not expected.
CSU Module/T1 Sync Splitter not expected: The 120A1 CSU Module or
the 401A T1 Sync Splitter is physically connected to the UDS1 board on
the back of the port carrier but the
Near-End CSU Type
field on the add
ds1 form has not been administered as
integrated
.
If the 120A1 CSU Module or the 401A T1 Sync Splitter is to be used, use
the change ds1 command to change the
Near-End CSU Type
field to
integrated
. Otherwise, physically remove the 120A1 CSU Module or the
401A T1 Sync Splitter from the back of the port carrier.
E1 Synchronization Splitter not expected: The 402A or 403A E1
Synchronization Splitter is physically connected to the UDS1 board on the
back of the port carrier but the
E1 Sync-Splitter?
field on the add ds1
form has not been administered as
y
.
If the 402A or 403A E1 Synchronization Splitter is to be used, use the
change ds1 command to change the
E1 Sync-Splitter?
field to
y
.
Otherwise, physically remove the 402A or 403A E1 Synchronization
Splitter from the back of the port carrier.
l. Error Type 1302 — DS1 configuration error. Attempting to use the 120A1
CSU Module with a UDS1 circuit pack that is configured for 32-channel
(2.048 Mbps) operation. The CSU Module only works with a DS1 board
configured for 24-channel (1.544 Mbps) operation in the United States of
America.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...