555-233-119
968
Issue 5 October 2002
14
16
40
2000
2003
2004
FAIL
In the case of Error Code 40, the Crosstalk Test failed because the data
received over the connection did not match the data sent over the connection
(data was corrupted). In the case of Error Code 2000, 2003, and 2004, the
crosstalk test failed because the data looped over the connection was not
received (data was lost).
1. Determine which of the DATA-CHLs are in use for some other function
(that is, CDR Link, System Printer Link, Journal Printer Link, PMS Link,
or secondary administration terminal connection) as described
previously in the
‘‘Status of Data Channels’’
section.
2. Note the test result for Test #111 in the Short Test Sequence for the
target DATA-CHL and refer to Steps 3 and/or 4 to determine the
appropriate actions to take based on those results.
3. If the result of Test #111 is PASS, then the most likely problem is that the
TDM Bus or Tone-Clock circuit pack is defective.
a. Check for the existence of TDM Bus (TDM-BUS) and/or Tone-Clock
circuit pack (TONE-BD, TONE-PT, and TDM-CLK) errors and alarms.
If they exist:
1. Refer to the corresponding Maintenance documentation to clear
the errors and alarms.
2. Repeat the test.
b. If TDM Bus (TDM-BUS) and/or Tone-Clock circuit pack (TONE-BD,
TONE-PT, and TDM-CLK) errors and alarms do not exist, investigate
the possibility that the target DATA-CHL, or the Processor circuit pack
is defective as described in Step 4.
Table 176.
TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...