EXT-DEV ADMIN? Y (External Device Alarm)
Issue 5 October 2002
1187
555-233-119
EXT-DEV ADMIN? Y (External Device
Alarm)
NOTE:
Use this Maintenance Object when the
External Device Alarm
Admin?
field on the change system-parameters customer-options form is
set to y. You must have INADS or INIT login permission to administer
EXT-DEV Alarm.
Generic 3i Maintenance circuit packs each have alarm leads which can be
connected to external devices such as Uninterruptible Power Supplies (UPS) or
adjuncts such as AUDIX. Certain conditions on the external device close the
contacts on the alarm leads to notify the switch which in turn originates an
EXT-DEV alarm.
The special locations UUmajor and UUminor are used to designate the major or
minor maintenance board alarm connection for cabinet UU. The major/minor
designation specifies the port, not the alarm level associated with the connection;
for example, the “major” port can be administered as a major, minor, or warning
alarm, and the “minor” port can be administered as a major, minor or warning
alarm. In addition Analog line ports can also be administered as external device
alarms.
NOTE:
An unadministered maintenance board external device alarm port, that is
sensing a contact closure will have an entry in the Error Log and in the
Alarm Log. INADS will not receive warning alarms.
The Processor monitors the EXT-DEV alarm leads. The system only recognizes
pairs connected to the 1M and 1m (ALARM MONITOR) leads. Refer to the
DEFINITY Communications System Generic 1 and Generic 3i Wiring,
555-204-111, for more details.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
EXT-DEV
MAJOR
test eda-external-device-alrm physical
location
External Device Alarm
EXT-DEV
MINOR
test eda-external-device-alrm physical
location
External Device Alarm
EXT-DEV
WARNING
test eda-external-device-alrm physical
location
External Device Alarm
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...